The CELLERAX LS-2X7 is driven by a Siemens S7-series PLC and the proprietary CELLINA Version 2 software, offering a seamless blend of automation power and operator-friendly design.
The proprietary CELLINA control software provides a comprehensive suite of tools for fermentation management. Its intuitive 15-inch touchscreen interface delivers real-time visualization of all process parameters, while the underlying Siemens S7 PLC ensures deterministic, millisecond-level control reliability.
CELLINA supports multi-step recipe programming with automatic transitions based on custom trigger conditions. Operators can define complex cultivation protocols that seamlessly shift between growth phases, adjusting feed rates, gas flow, pH setpoints, and agitation speeds without manual intervention.
The system also features comprehensive alarm management to detect and alert operators to any process deviations in real time, ensuring the safety and integrity of every culture run.
Two pillars of intelligent automation power the CELLERAX LS-2X7: the CELLINA software platform and Fuzzy PID temperature regulation.
The proprietary control software provides a comprehensive suite of tools for fermentation management. Multi-step recipe programming with automatic transitions based on custom trigger conditions gives operators full flexibility in designing complex cultivation protocols.
Real-time visualization of all process parameters on a 15-inch touchscreen, combined with comprehensive alarm management and data logging capabilities, ensures complete process oversight.
Temperature regulation employs an advanced Fuzzy PID algorithm that adapts control parameters dynamically to the current setpoint and process conditions. This intelligent approach delivers superior resistance to thermal fluctuations compared to conventional PID controllers.
The system maintains process temperature within a remarkable 0.1 °C accuracy across the full 5 to 80 °C operating range, integrating an internal heater with cold water circulation from an external chiller for rapid response.
The CELLERAX LS-2X7 employs world-renowned Hamilton sensors from Switzerland and Siemens transmitters from Germany, delivering the accuracy and reliability demanded by modern bioprocessing.
Hamilton VisiFerm optical sensor provides real-time DO measurement with 1% accuracy across the full range — no polarisation time, no membrane replacement required.
Hamilton EasyFerm pH sensor delivers reliable measurement across the entire pH range, ensuring accurate acid/base dosing control for optimal culture conditions throughout fermentation.
Siemens temperature transmitters with Fuzzy PID control maintain process temperature within 0.1 °C accuracy. Internal heater plus external chiller circulation ensures rapid response.
Mass Flow Controller (MFC) regulates air supply at 1–2 VVM. Integrated foam detection and antifoam dosing protect culture integrity throughout the fermentation cycle.
DO & pH Sensors — VisiFerm & EasyFerm series
PLC & Temperature Transmitters — S7 Series
Peristaltic Pumps — Precision dosing systems
Peristaltic Pumps — Fluid handling excellence
Discover how CELLINA v2 and Fuzzy PID can transform your fermentation workflows.